Intel® Server System SR9000MK4U Product Guide Intel Order Number D71314-004
x Intel® Server System SR9000MK4U Product GuidePowering the System On and OffPowering On the System Power1. Connect the power cables to AC input power
78 Intel® Server System SR9000MK4U Product Guide5. Loosen the two captive screws on the exterior of the system. One screw is on each side of the syste
Intel® Server System SR9000MK4U Product Guide 797. Lift up the front end of the power supply box first, then lift the power supply box from the system
80 Intel® Server System SR9000MK4U Product GuideInstalling the Power Supply BoxThese steps assume you have just removed the power supply box, as descr
Intel® Server System SR9000MK4U Product Guide 813. Tighten the two captive screws at the bottom of the power supply box. See the figure below.Figure 8
82 Intel® Server System SR9000MK4U Product GuideFigure 82. Locating the CPU1 / CPU2 MVR Connection6. Connect the IDE cable from the main board. See le
Intel® Server System SR9000MK4U Product Guide 839. Determine your next course of action and refer to the appropriate steps:— If you are following thes
84 Intel® Server System SR9000MK4U Product Guide1. Loosen the two screws that hold the power supply support in place. See the figure below.Figure 84.
Intel® Server System SR9000MK4U Product Guide 853. Determine your next course of action and refer to the appropriate steps:— If you are following thes
86 Intel® Server System SR9000MK4U Product Guide2. Tighten the two captive screws at the bottom of the power supply support. See the figure below.Figu
Intel® Server System SR9000MK4U Product Guide 87Installing and Removing the Hard Drive Backplane CoverBefore beginning these steps, power down your se
Intel® Server System SR9000MK4U Product Guide xiContentsSafety Information ...
88 Intel® Server System SR9000MK4U Product GuideInstalling the Hard Drive Backplane CoverThese steps assume the top cover is already removed from the
Intel® Server System SR9000MK4U Product Guide 89Figure 90. Checking the Backplane Cover Latches4. Determine your next course of action and refer to th
90 Intel® Server System SR9000MK4U Product GuideRemove these components, in order, before beginning the steps below. The steps below do not guide you
Intel® Server System SR9000MK4U Product Guide 912. Determine your next course of action and refer to the appropriate steps:— If you are following thes
92 Intel® Server System SR9000MK4U Product GuideRemove these components, in order, before beginning the steps below. The steps below do not guide you
Intel® Server System SR9000MK4U Product Guide 93Installing the PCI Card DividerThese steps assume you have just removed the PCI card divider, as descr
94 Intel® Server System SR9000MK4U Product Guide3. Install the CPU1 / CPU2 MVR cable. See the figure below to locate the connection point on the serve
Intel® Server System SR9000MK4U Product Guide 95Installing and Removing the Air Flow GuideBefore beginning these steps, power down your server system
96 Intel® Server System SR9000MK4U Product Guide1. Pull the air flow guide upward to remove it from the system. See the figure below.Figure 95. Removi
Intel® Server System SR9000MK4U Product Guide 97Installing the Air Flow GuideThese steps assume you have removed the air flow guide, as described in “
xii Intel® Server System SR9000MK4U Product GuideInstalling the Front Bezel ...
98 Intel® Server System SR9000MK4U Product Guide✧ The KVM card, if necessary. For instructions, see “Installing the KVM Card” on page 90.✧ All install
Intel® Server System SR9000MK4U Product Guide 99• The air flow guide. For instructions, see “Removing the Air Flow Guide” on page 95.• All installed f
100 Intel® Server System SR9000MK4U Product Guide2. Loosen the two captive screws on the interior of the system, as shown by the figure below.Figure 9
Intel® Server System SR9000MK4U Product Guide 1014. Determine your next course of action and refer to the appropriate steps:— If you are following the
102 Intel® Server System SR9000MK4U Product Guide2. Tighten the two screws at the bottom of the fan box, as shown by the figure below.Figure 101. Tigh
Intel® Server System SR9000MK4U Product Guide 1034. Determine your next course of action and refer to the appropriate steps:— If you are following the
104 Intel® Server System SR9000MK4U Product Guide• All installed power supplies. For instructions, see “Removing a Power Supply” on page 70.• The powe
Intel® Server System SR9000MK4U Product Guide 1051. Disconnect all cables from the hard drive backplane.2. Remove the four screws from the hard drive
106 Intel® Server System SR9000MK4U Product Guide3. Pull up slightly on the hard drive backplane to unhook the 12 hooks that hold the backplane into p
Intel® Server System SR9000MK4U Product Guide 107Installing the Hard Drive BackplaneThese steps assume you have removed the air flow guide, as describ
Intel® Server System SR9000MK4U Product Guide xiiiRemoving the KVM Card ...
108 Intel® Server System SR9000MK4U Product Guide3. Install the four screws on the hard drive backplane to secure the backplane to the system. See the
Intel® Server System SR9000MK4U Product Guide 109✧ The hard drive backplane cover. For instructions, see “Installing the Hard Drive Backplane Cover” o
110 Intel® Server System SR9000MK4U Product GuideInstalling and Removing a ProcessorBefore beginning these steps, power down your server system and un
Intel® Server System SR9000MK4U Product Guide 111Removing a ProcessorTo perform this procedure, you first need to remove:• The top cover. For instruct
112 Intel® Server System SR9000MK4U Product Guide1. Lift up on the MVR handles to remove them. One handle is on each side of the MVR. See the figure b
Intel® Server System SR9000MK4U Product Guide 1135. If necessary, disassemble the processor. For instructions, see “Disassembling a Processor Assembly
114 Intel® Server System SR9000MK4U Product Guide• The KVM card, if it is installed. For instructions, see “Removing the KVM Card” on page 89.• All in
Intel® Server System SR9000MK4U Product Guide 1154. Snap the pin shroud over the processor, verifying that the positioning pins of the pin shroud alig
116 Intel® Server System SR9000MK4U Product Guide6. While holding the spring clip in place on the processor, align the positioning pins on processor w
Intel® Server System SR9000MK4U Product Guide 1179. Install the bolster plate onto the LGA terminal. See the figure below.Figure 114. Installing the B
xiv Intel® Server System SR9000MK4U Product GuideHow to Use Selview to Read the System Event Log ... 160
118 Intel® Server System SR9000MK4U Product Guide11. Carefully set the processor assembly into place on the main board, aligning the heatsink screws w
Intel® Server System SR9000MK4U Product Guide 11914. Remove the protective cover from the LGA terminal on the back of the MVR. See the figure below.Fi
120 Intel® Server System SR9000MK4U Product Guide16. Use a Torx-15 screwdriver to tighten the four screws at the corners of the MVR. Use a torque leve
Intel® Server System SR9000MK4U Product Guide 12119. Determine your next course of action and refer to the appropriate steps:— If you are following th
122 Intel® Server System SR9000MK4U Product GuideDisassembling a Processor AssemblyBefore beginning this procedure, follow all steps necessary to remo
Intel® Server System SR9000MK4U Product Guide 1236. Lift the bolster plate from the LGA terminal on the underside of the heat sink / processor assembl
124 Intel® Server System SR9000MK4U Product Guide8. Lift the spring clip from the processor. See the following figure.Figure 126. Removing the Spring
Intel® Server System SR9000MK4U Product Guide 125Installing and Removing the Mounting PlateBefore beginning these steps, power down your server system
126 Intel® Server System SR9000MK4U Product GuideThe steps do not guide you through reinstalling the components you are removing or disconnecting in t
Intel® Server System SR9000MK4U Product Guide 127Installing the Mounting PlateThese instructions assume your server system is disassembled and you are
Intel® Server System SR9000MK4U Product Guide xvConsignes de sécurité sur le serveur ...
128 Intel® Server System SR9000MK4U Product Guide— The PCI card divider. For instructions, see “Installing the PCI Card Divider” on page 93.— The KVM
Intel® Server System SR9000MK4U Product Guide 129Installing and Removing Chassis HandlesInstalling Chassis HandlesTwo handles can be installed on each
130 Intel® Server System SR9000MK4U Product Guide
1314 Configuration Software and UtilitiesThe Extensible Firmware Interface (EFI) Boot ManagerThe EFI boot manager enables the user to control the boot
132 Intel® Server System SR9000MK4U Product GuideTable 19. Boot Maintenance Menu OptionsOption DescriptionBoot from a File Automatically adds EFI appl
Intel® Server System SR9000MK4U Product Guide 133Delete Boot Options Deletes a specific boot option or all boot options. To delete boot options: 1. Us
134 Intel® Server System SR9000MK4U Product GuideThe Extensible Firmware Interface (EFI) ShellThe EFI Shell is an EFI application that enables other E
Intel® Server System SR9000MK4U Product Guide 135EFI shell commands are listed below.Table 20. EFI Shell CommandsCommand Descriptionalias [-d|-v|-b][A
136 Intel® Server System SR9000MK4U Product Guidehelp [-b]|[cmd] Displays command help information.hexedit [[-f]FileName|[-d DiskName Offset Size]|[-m
Intel® Server System SR9000MK4U Product Guide 137LSI* SAS UtilitySee also “Integrated RAID User's Guide” at http://www.lsilogic.com. Formatting a
xvi Intel® Server System SR9000MK4U Product Guide
138 Intel® Server System SR9000MK4U Product Guide4. The SAS Topology is displayed. Select Direct Attach Devices and press the <Enter> key.5. Sel
Intel® Server System SR9000MK4U Product Guide 1396. When the device properties are displayed, select Format and press the <Enter> key.7. When th
140 Intel® Server System SR9000MK4U Product Guide8. After the format has completed, press the <Esc> key several times, until you see the followi
Intel® Server System SR9000MK4U Product Guide 141Figure 131. Firmware Update Block DiagramAF001197Integrated ROM file (The filethat integrates the upd
142 Intel® Server System SR9000MK4U Product GuideFwupdate provides the following functions.• SAL/BMC updateThis function updates the SAL (FHW/SAL Spoo
Intel® Server System SR9000MK4U Product Guide 143Table 21. Command Line DescriptionOption FunctionFile name Integrated ROM file name. The format is as
144 Intel® Server System SR9000MK4U Product GuideExecution ScreenFigure 133. FWUPDATE Execution Screenfs0:>fwupdate fw_01-02_01-03.rom[Enter]Firmwa
Intel® Server System SR9000MK4U Product Guide 145Using System SetupThis section describes the System Setup. This utility provides a way for the user t
146 Intel® Server System SR9000MK4U Product GuideNavigating Setup Utility Screens The system setup utility consists of ten primary menus. Each menu oc
Intel® Server System SR9000MK4U Product Guide 147When the power button is pressed and released while the main power is on, the power turns off or the
Intel® Server System SR9000MK4U Product Guide xviiList of FiguresFigure 1. Intel® Server System SR9000MK4U Three Dimensional View...
148 Intel® Server System SR9000MK4U Product Guide When the system is configured with AfterPowerFailure = On, the power turns on automatically in the f
Intel® Server System SR9000MK4U Product Guide 149Devices ScreenTable 27 describes the menu items available on the Devices screen. Default values appea
150 Intel® Server System SR9000MK4U Product GuideServer Management ScreenTable 28 describes the menu items available on the Server Management screen.
Intel® Server System SR9000MK4U Product Guide 151System Information ScreenSystem information as firmware version, and board, chassis, and product info
152 Intel® Server System SR9000MK4U Product Guide3. Choose “Console Redirection”:4. Choose “COM1 Console Redirection”:5. Set the COM1 Speed to 9600/19
1535 TroubleshootingInitial Troubleshooting StepsThe Intel® Server System SR9000MK4U implements indicators to display the system status. These are use
154 Intel® Server System SR9000MK4U Product GuideCooling Fault LED System powers on, but then turns off quickly. Cooling Fault LED (orange) is on.Chec
Intel® Server System SR9000MK4U Product Guide 155Processor System does not recognize part of the processors that were installed.Check that the process
156 Intel® Server System SR9000MK4U Product GuideCollecting System State InformationIf the information in the table above did not resolve your problem
Intel® Server System SR9000MK4U Product Guide 157Power Off State1. Power up the system.2. Wait for the EFI shell to begin.3. Use the selview utility t
xviii Intel® Server System SR9000MK4U Product GuideFigure 43. Removing Optical Drive from Server ...
158 Intel® Server System SR9000MK4U Product GuideEFI Shell Working State1. Read the POST code. For instructions, see “How to Read the POST Codes” on p
Intel® Server System SR9000MK4U Product Guide 159System Hang Status1. Read the POST code. For instructions, see “How to Read the POST Codes” on page 1
160 Intel® Server System SR9000MK4U Product GuideHow to Use Selview to Read the System Event Log1. Use the EFI utility “selview” to acquire system eve
Intel® Server System SR9000MK4U Product Guide 161— Select an appropriate drive letter in the “Save in” list.— Enter “security.evt” as the file name.13
162 Intel® Server System SR9000MK4U Product Guidesecurity.csvap.evtap.csvsystem32.txtdrivers.txt30. Use Notepad to confirm the following files contain
163Appendix A: Console SetupOn-board VGAThe Intel® Server System SR9000MK4U server can output the SAL and EFI displays to on-board VGA. This subsectio
164 Intel® Server System SR9000MK4U Product Guide4. Select Onboard VGA from the VGA Menu. Set the option to either Enable or Disable. When you want to
Intel® Server System SR9000MK4U Product Guide 165Serial ConsoleThe Intel® Server System SR9000MK4U server supports headless function that redirects th
166 Intel® Server System SR9000MK4U Product Guide4. Select COM1 Console Redirection on the Console Redirection Menu screen.5. Select Headless Support
167Appendix B: CablingThis appendix provides a a brief guideline about how to correctly attach and detach cables to prevent damage to the cable, or to
Intel® Server System SR9000MK4U Product Guide xixFigure 90. Checking the Backplane Cover Latches ...
168 Intel® Server System SR9000MK4U Product GuideCable ConnectionsFigure 136. Connections Near Power Supply Box and PCI Card DividerNote: The figure a
Intel® Server System SR9000MK4U Product Guide 169Figure 138. IDE Connection and Cable RoutingNote: The figure above shows the system with the fans rem
170 Intel® Server System SR9000MK4U Product GuideA. Control panel power connection on hard drive backplaneC. Control panel data connector on server bo
171Appendix C: POST CodesTable 31. POST Codes Generated by the BMC and Logged at the Seven Segment LEDCode Descriptions ClassificationOperation to Rec
172 Intel® Server System SR9000MK4U Product Guide1 A Active side file update error Error1 B Checksum error detected in active side Error1 C SRAM check
Intel® Server System SR9000MK4U Product Guide 1733Areserved3Breserved3 C Detailed log collection started by WDT overflow Error BMC Error3 D BMC restar
174 Intel® Server System SR9000MK4U Product Guide5 3 CPU3 Configuration Error (Disabled) Error, error event logged to SEL5 4 CPU3 Configuration Error
Intel® Server System SR9000MK4U Product Guide 1756 A PS0 Power Failure (Insufficient Resources) Error, error event logged to SEL6 B PS1 Power Failure
176 Intel® Server System SR9000MK4U Product Guide9 0 Multiple Machine Check Interrupt Error, error event logged to SEL9 1 MB Config Access Error (NDC3
Intel® Server System SR9000MK4U Product Guide 177A B reservedACreservedADreservedA E reservedAFreservedB7reservedB8reservedB9reservedB A reservedB B r
ii Intel® Server System SR9000MK4U Product GuideDisclaimer Information in this document is provided in connection with Intel® products. No license, ex
xx Intel® Server System SR9000MK4U Product GuideFigure 137. SATA Connections on Hard Drive Backplane ...
178 Intel® Server System SR9000MK4U Product Guide4 1EA Console initialization5 1F5 Chipset initializationMemory initialization6 1F4 Recovery SDA initi
Intel® Server System SR9000MK4U Product Guide 17932 0F5 Clear error flags in chipset33 0D0 EFI code shadowingEFI execution34 AF~15 EFI POST task execu
180 Intel® Server System SR9000MK4U Product Guide25 0x8017 Unexpected failure Error26 0x8018 Unexpected failure Error27 0x8019 Unexpected failure Erro
181Appendix D: Installation/Assembly Safety InstructionsEnglishThe power supply in this product contains no user-serviceable parts. Refer servicing on
182 Intel® Server System SR9000MK4U Product GuideAfter you have completed the six SAFETY steps above, you can remove the system covers. To do this:1.
Intel® Server System SR9000MK4U Product Guide 183DeutschBenutzer können am Netzgerät dieses Produkts keine Reparaturen vornehmen. Das Produkt enthält
184 Intel® Server System SR9000MK4U Product GuideSICHERHEISMASSNAHMEN: Immer wenn Sie die Gehäuseabdeckung abnehmen um an das Systeminnere zu gelange
Intel® Server System SR9000MK4U Product Guide 185FrançaisDas System wurde für den Betrieb in einer normalen Büroumgebung entwickelt. Der Standort soll
186 Intel® Server System SR9000MK4U Product GuideCONSIGNES DE SÉCURITÉ -Lorsque vous ouvrez le boîtier pour accéder à l'intérieur du système, sui
Intel® Server System SR9000MK4U Product Guide 187EspañolLe système a été conçu pour fonctionner dans un cadre de travail normal. L'emplacement ch
Intel® Server System SR9000MK4U Product Guide xxiList of TablesTable 1. Additional Information and Software ...
188 Intel® Server System SR9000MK4U Product GuideINSTRUCCIONES DE SEGURIDAD: Cuando extraiga la tapa del chasis para acceder al interior del sistema,
Intel® Server System SR9000MK4U Product Guide 189ItalianoExiste peligro de explosión si la pila no se cambia de forma adecuada. Utilice solamente pila
190 Intel® Server System SR9000MK4U Product GuideL'interruttore attivato/disattivato nel pannello anteriore non interrompe l'alimentazione i
Intel® Server System SR9000MK4U Product Guide 191Esiste il pericolo di un esplosione se la pila non viene sostituita in modo corretto. Utilizzare solo
192 Intel® Server System SR9000MK4U Product Guide
193Appendix E: Safety InformationWarning LabelsThe Intel® Server System SR9000MK4U contains several warning labels on the interior and exterior of the
194 Intel® Server System SR9000MK4U Product GuideA warning on the side of the chassis warns you that the chassis is heavy. Do not attempt to lift the
Intel® Server System SR9000MK4U Product Guide 195One of the following labels will be attached to your power supply.EnglishServer Safety InformationThi
196 Intel® Server System SR9000MK4U Product GuideSafety Warnings and CautionsTo avoid personal injury or property damage, before you begin installing
Intel® Server System SR9000MK4U Product Guide 197Site SelectionThe system is designed to operate in a typical office environment. Choose a site that i
xxii Intel® Server System SR9000MK4U Product Guide
198 Intel® Server System SR9000MK4U Product GuidePower and Electrical WarningsCautions:• The power button, indicated by the stand-by power marking, DO
Intel® Server System SR9000MK4U Product Guide 199System Access WarningsCaution: To avoid personal injury or property damage, the following safety inst
200 Intel® Server System SR9000MK4U Product GuideRack Mount WarningsThe equipment rack must be anchored to an unmovable support to prevent it from tip
Intel® Server System SR9000MK4U Product Guide 201Other HazardsBattery ReplacementCaution: There is the danger of explosion if the battery is incorrect
202 Intel® Server System SR9000MK4U Product GuideDeutschSicherheitshinweise für den ServerDas vorliegende Dokument bezieht sich auf Intel® Serverplati
Intel® Server System SR9000MK4U Product Guide 203Zielbenutzer der AnwendungDieses Produkt wurde in seiner Eigenschaft als IT-Gerät getestet, das in Bü
204 Intel® Server System SR9000MK4U Product GuideHandhabung von GerätenBeachten Sie zur Vermeidung von Verletzungen oder Beschädigungen an den Geräten
Intel® Server System SR9000MK4U Product Guide 205Hinweis für Netzkabel Wenn kein Netzkabel mit dem Produkt geliefert wurde, kaufen Sie ein Kabel, das
206 Intel® Server System SR9000MK4U Product GuideEinbauen von Hot-Plug-Komponenten sorgfältig vor, um nicht mit heißen Komponenten in Berührung zu kom
Intel® Server System SR9000MK4U Product Guide 207Andere GefahrenBatterieaustauschVorsicht: Wird die Batterie unsachgemäß ausgetauscht, besteht Explosi
11 Intel® Server System SR9000MK4U Chassis OverviewThe Intel® Server System SR9000MK4U as shown in Figure 1 is a compact, high-density rack-mount serv
208 Intel® Server System SR9000MK4U Product GuideFrançaisConsignes de sécurité sur le serveurCe document s’applique aux cartes serveur Intel®, au châs
Intel® Server System SR9000MK4U Product Guide 209Domaines d’utilisation prévusCe produit a été testé comme équipement informatique (ITE) et peut être
210 Intel® Server System SR9000MK4U Product GuideAlimentation et avertissements en matière d’électricitéAttention: Le bouton d’alimentation, indiqué p
Intel® Server System SR9000MK4U Product Guide 211Avertissements sur l’accès au systèmeAttention: Pour éviter de vous blesser ou d’endommager votre équ
212 Intel® Server System SR9000MK4U Product GuideAvertissements sur le montage en rackLe rack doit être fixé à un support inamovible pour éviter qu’il
Intel® Server System SR9000MK4U Product Guide 213Refroidissement et ventilationAttention: Routez les câbles avec précaution comme indiqué pour minimis
214 Intel® Server System SR9000MK4U Product GuideEspañolInformación de seguridad del servidorEste documento se aplica a las tarjetas de servidor de In
Intel® Server System SR9000MK4U Product Guide 215Aplicaciones y usos previstosEste producto ha sido evaluado como equipo de tecnología informática (IT
216 Intel® Server System SR9000MK4U Product GuideAdvertencias de alimentación y eléctricasPrecaución: El botón de encendido, indicado con la marca del
Intel® Server System SR9000MK4U Product Guide 217• Los cables de la fuente de alimentación deben estar conectados a los enchufes con una toma de tierr
2 Intel® Server System SR9000MK4U Product GuideChassis DescriptionFeatures are outlined in Table 3.Table 3. Chassis Feature SummaryFeature CommentServ
218 Intel® Server System SR9000MK4U Product GuideAdvertencias sobre el montaje en bastidorEl bastidor del equipo se debe sujetar con un soporte fijo p
Intel® Server System SR9000MK4U Product Guide 219Enfriamiento y circulación de airePrecaución: El tendido de los cables debe realizarse cuidadosamente
220 Intel® Server System SR9000MK4U Product Guide简体中文 服务器安全信息 本文档适用于 Intel® 服务器主板、Intel® 服务器机箱(基座和机架固定件)和已安装的外设。为减少人身伤害、电击、火以及设备毁坏的危险,请在安装或维护 Intel® 服
Intel® Server System SR9000MK4U Product Guide 221预期应用使用 根据评估,本产品为信息技术设备 (ITE),可安装在办公室、学校、计算机房和类似的商业场所。本产品对于非 ITE 应用的其他产品种类和环境(如医疗、工业、住宅、报警系统和测试设备)的适用性
222 Intel® Server System SR9000MK4U Product Guide为避免电击,请在打开服务器之前,关闭服务器并断开服务器上连接的电源线、电信系统、网络和调制解调器。 电源线警告 如果产品未提供交流电线,请购买一根您所在国家批准使用的交流电线。 注意事项 为避
Intel® Server System SR9000MK4U Product Guide 223 注意事项 为避免受伤,请勿触摸运转的风机叶片。如果系统的风机上配有防护装置,请勿卸下风机防护装置运行系统。 机架固定件警告 设备的机架须固定在稳固的支座上,以防从中安装服务器或设备时倒塌。须按照
224 Intel® Server System SR9000MK4U Product Guide其他危险 替换电池 注意事项 不正确替换电池可能导致爆炸危险。替换电池时,请只使用设备生产商推荐使用的电池。 请按当地法规处置电池。 请勿对电池充电。 请勿拆卸、刺穿或以其他方式损坏电池。 冷
225Appendix F: Getting HelpWorld Wide Webhttp://support.intel.com/support/motherboards/server/SR9000MK4U.TelephoneAll calls are billed per incident, l
226 Intel® Server System SR9000MK4U Product GuideIn Asia-Pacific RegionAustralia... 1800 649931Cambodia.. 63 2 636 9797 (via Philippines)China ...
Intel® Server System SR9000MK4U Product Guide 227Colombia... Contact AT&T USA at 01 800 911 0010. Once connected, dial 800 843 4481Costa Rica . Co
Intel® Server System SR9000MK4U Product Guide 3External Chassis FeaturesSystem control buttons and indicators are located in several places on the cha
228 Intel® Server System SR9000MK4U Product Guide
229Appendix G: Regulatory and Compliance InformationTo ensure regulatory compliance, you must adhere to the assembly instructions in this guide to ens
230 Intel® Server System SR9000MK4U Product Guide• GS License (Germany) • GOST R 50377-92 - License (Russia) • Belarus License (Belarus)• Ukraine Lice
Intel® Server System SR9000MK4U Product Guide 231• C-Tick Declaration of Conformity (Australia)• MED Declaration of Conformity (New Zealand)• BSMI Cer
232 Intel® Server System SR9000MK4U Product GuideAny changes or modifications not expressly approved by the grantee of this device could void the user
Intel® Server System SR9000MK4U Product Guide 233BSMI (Taiwan)The BSMI Certification Marking and EMC warning is located on the outside rear area of th
234 Intel® Server System SR9000MK4U Product GuideRegulated Specified ComponentsTo maintain the UL listing and compliance to other regulatory certifica
Intel® Server System SR9000MK4U Product Guide 235Restriction of Hazardous Substances (RoHS) ComplianceIntel has a system in place to restrict the use
236 Intel® Server System SR9000MK4U Product Guide
4 Intel® Server System SR9000MK4U Product GuideChassis FrontFigure 2 shows the front view of the chassis with the snap-on bezel in place. The bezel pr
Intel® Server System SR9000MK4U Product Guide 5Front PanelThe front panel is located below the slimline optical drive on the left-side of the chassis
6 Intel® Server System SR9000MK4U Product GuideOptical Drive BayThe slim-line optical drive (DVD-ROM / CD-ROM drive) is inserted from the front of the
Intel® Server System SR9000MK4U Product Guide 7The hard drive carriers contain light-pipes that allow dual-color LED indicators to display through the
iiiSafety InformationImportant Safety InstructionsRead all caution and safety statements in this document before performing any of the instructions. S
8 Intel® Server System SR9000MK4U Product GuideMemory BoxIn memory mirror mode, memory box 0 is paired with memory box 1. Memory box 2 is paired with
Intel® Server System SR9000MK4U Product Guide 9Chassis RearFigure 7 shows the features found on the rear panel.Figure 7. Chassis Rear ViewAF001087 A
10 Intel® Server System SR9000MK4U Product GuideTable 5. NIC LEDsItem LED Color State DescriptionGigabit Ether, ports GbE1 and GbE0ACT/LNK (right LED)
Intel® Server System SR9000MK4U Product Guide 11Internal LayoutThe following diagram shows the location of components inside of the server system.Figu
12 Intel® Server System SR9000MK4U Product GuideInternal Chassis FeaturesPower Supply SubsystemThe 12 V hot-swap power supply modules are rated at 139
Intel® Server System SR9000MK4U Product Guide 13Each power supply contains three LEDs on the top surface. The LED locations and descriptions are as fo
14 Intel® Server System SR9000MK4U Product GuideCooling SubsystemThe cabinet inlets have hot-swappable, 5+1 redundant fans for cooling. 120 mm x 38 mm
Intel® Server System SR9000MK4U Product Guide 15PCI Card SlotFigure 11. PCI Card Slot IndicatorA Power LED Indicates PCI slot status is active.B Atten
16 Intel® Server System SR9000MK4U Product Guide
172 Intel® Server System SR9000MK4U Board Set OverviewThe board set for the Intel® Server System SR9000MK4U consists of one main board, four memory bo
iv Intel® Server System SR9000MK4U Product GuideWarningsHeed safety instructions: Before working with your server product, whether you are using this
18 Intel® Server System SR9000MK4U Product GuideMain BoardFigure 13. Main Board LayoutAF001095ProcessorSocket0NDC0NDC1FAN0VHDM0PCI slot1PCI slot2PCI s
Intel® Server System SR9000MK4U Product Guide 19Table 7. Main Board ComponentsBoard LocationComponent DescriptionP1/P2 Hitachi* NDC Node Controller: •
20 Intel® Server System SR9000MK4U Product GuideP9 LSI Logic* SAS1068 PCI-X* to 3 Gb/s 8-port SAS controller. Four of the eight ports are used. • 1.5
Intel® Server System SR9000MK4U Product Guide 21Table 8. Main Board External I/O ConnectorsBoard LocationConnector DescriptionE1 Serial RS232C D-sub 9
22 Intel® Server System SR9000MK4U Product GuideConfiguration RestrictionsNote: When one or two 75-watt PCI-Express* graphics cards are installed, the
Intel® Server System SR9000MK4U Product Guide 23Processor ConfigurationsFigure 14 shows the top view of main board, indicating the processor locations
24 Intel® Server System SR9000MK4U Product GuideMemory Box CardFigure 15. Memory Box Card LayoutTable 12. Memory Box Card ComponentsBoard Location Com
Intel® Server System SR9000MK4U Product Guide 25DIMM ConfigurationsFigure 16 shows the DIMM locations within each memory box. One memory box houses ei
26 Intel® Server System SR9000MK4U Product GuideThree memory modes are available. The memory mode is selected depending on the number of memory boxes
Intel® Server System SR9000MK4U Product Guide 27In the path to 1-B no new memory box is needed and therefore has a lower cost for capacity addition.Me
Intel® Server System SR9000MK4U Product Guide vInstalling or removing jumpers: A jumper is a small plastic encased conductor that slips over two jumpe
28 Intel® Server System SR9000MK4U Product GuideFigure 17. Memory Upgrade PathAF001103Upgrade PathMC MC NDC NDC Single Mode 1MMR/8DIMM Upgrade Path
Intel® Server System SR9000MK4U Product Guide 29Hard Drive BackplaneFigure 18. Hard Drive Backplane Top ViewFigure 19. Hard Drive Backplane Bottom Vie
30 Intel® Server System SR9000MK4U Product GuideHard Drive PopulationThe on-board SAS controller is connected to four of the eight hard drives, drives
Intel® Server System SR9000MK4U Product Guide 31Table 17. Front Panel Board ConnectorsBoard Location Connector DescriptionC1 HMC2 DVDC3 USB4/5 USB Typ
32 Intel® Server System SR9000MK4U Product Guide
333 Installing and Removing ComponentsTo complete many of the installation or removal procedures in this chapter, you will need to first install or re
34 Intel® Server System SR9000MK4U Product GuideInstalling and Removing the Front BezelYou will need to remove the front bezel to perform the followin
Intel® Server System SR9000MK4U Product Guide 35Installing the Front Bezel1. Set the left or right side of the bezel into place at the front of the sy
36 Intel® Server System SR9000MK4U Product GuideInstalling and Removing the Top CoverYou will need to remove the top cover to perform the following op
Intel® Server System SR9000MK4U Product Guide 37Installing the Top Cover1. Place the front edge of the cover on the chassis.2. Lower the rear of the c
vi Intel® Server System SR9000MK4U Product Guide
38 Intel® Server System SR9000MK4U Product GuideInstalling a Hard DriveCaution: Before performing the procedures written in this chapter, except for w
Intel® Server System SR9000MK4U Product Guide 39Figure 26. Mounting a Hard Drive7. Open the hard drive carrier lever if it is closed. 8. Slide the har
40 Intel® Server System SR9000MK4U Product GuideRemoving a Hard DriveCautions:• Before performing the procedures in this chapter, except for when hot-
Intel® Server System SR9000MK4U Product Guide 414. Remove the four screws at the sides of the hard drive carrier. Two screws are at each side of the c
42 Intel® Server System SR9000MK4U Product GuideHot-swapping a Hard DriveNote: Remove only the failed drive. Removing the wrong drive could cause the
Intel® Server System SR9000MK4U Product Guide 43Installing a Memory BoxTo perform this procedure, you will first need to remove the front bezel. The s
44 Intel® Server System SR9000MK4U Product Guide6. Carefully slide the memory box into the bay. When the memory box is correctly inserted the notches
Intel® Server System SR9000MK4U Product Guide 45Removing a Memory BoxTo perform this procedure, you will first need to remove the front bezel. The ste
46 Intel® Server System SR9000MK4U Product GuideHot-swapping a Memory BoxTo perform this procedure, you will first need to remove the front bezel. The
Intel® Server System SR9000MK4U Product Guide 471. Remove the front bezel. For instructions, see “Removing the Front Bezel” on page 34.2. Push the hot
viiPrefaceAbout this ManualThank you for purchasing and using Intel® server products. This manual is written for system technicians who are responsibl
48 Intel® Server System SR9000MK4U Product GuideInstalling and Removing DIMMsDIMM Installation GuidelinesEach installed memory box must have either fo
Intel® Server System SR9000MK4U Product Guide 49Installing DIMMsTo perform this procedure, you will first need to remove:• The front bezel• The memory
50 Intel® Server System SR9000MK4U Product GuideRemoving DIMMsTo perform this procedure, you will first need to remove:• The front bezel• The memory b
Intel® Server System SR9000MK4U Product Guide 51Installing and Removing an Optical DriveInstalling an Optical DriveTo perform this procedure, you will
52 Intel® Server System SR9000MK4U Product Guide4. With the rear of the optical drive facing you, as shown by letter “A” below, install the left side
Intel® Server System SR9000MK4U Product Guide 53Removing the Optical DriveTo perform this procedure, you will first need to remove the front bezel. Th
54 Intel® Server System SR9000MK4U Product Guide4. Push the lever to release the drive from the bracket. See letter “A” in the figure below.Figure 44.
Intel® Server System SR9000MK4U Product Guide 55Installing and Removing a FanYou will need to remove the fan(s) to perform the following operations:•
56 Intel® Server System SR9000MK4U Product Guide3. Note the fan orientation in the figure below to make sure you insert the fan correctly. Insert the
Intel® Server System SR9000MK4U Product Guide 57Removing a FanTo perform this procedure, you will first need to remove the top cover. The steps below
viii Intel® Server System SR9000MK4U Product GuideProduct AccessoriesYou may need or want to purchase one or more of the following accessory items for
58 Intel® Server System SR9000MK4U Product Guide5. Determine your next course of action and refer to the appropriate steps:— If you have removed a fan
Intel® Server System SR9000MK4U Product Guide 59Installing and Removing a PCI CardYou will need to remove the PCI card(s) to perform the following ope
60 Intel® Server System SR9000MK4U Product Guide4. Push the PCI card lock firmly to unlock the card or the slot cover. See the figure below.Figure 51.
Intel® Server System SR9000MK4U Product Guide 616. Install the PCI card. See Figure 54.— For a short-length card, insert the PCI card firmly into the
62 Intel® Server System SR9000MK4U Product Guide7. Pull the PCI card lock firmly until it clicks into place. See the figure below.Figure 55. Locking a
Intel® Server System SR9000MK4U Product Guide 63Removing a PCI CardTo perform this procedure, you will first need to remove the top cover. The steps b
64 Intel® Server System SR9000MK4U Product Guide3. Push the PCI card lock firmly to unlock the PCI card. See the figure below.Figure 58. Unlocking a P
Intel® Server System SR9000MK4U Product Guide 655. Insert the slot cover over the opening at the rear of the chassis.Note: Be sure to insert a slot co
66 Intel® Server System SR9000MK4U Product Guide7. Close the PCI caution plate. See the figure below.Figure 62. Closing the PCI Caution Plate8. Determ
Intel® Server System SR9000MK4U Product Guide 67Hot-Plugging a PCI CardTo perform this procedure, you will first need to remove the top cover. The ste
Intel® Server System SR9000MK4U Product Guide ixSee also the Resource CD that came with your server system.DIMMs that have been tested with this produ
68 Intel® Server System SR9000MK4U Product GuideInstalling and Removing a Power SupplyYour system was shipped to you with two power supplies installed
Intel® Server System SR9000MK4U Product Guide 69Figure 64. Removing a Power Supply Filler3. Simultaneously push the two levers on the top of the power
70 Intel® Server System SR9000MK4U Product Guide5. Push down the two levers on the top of the power supply to lock it into place. See letter “A” in th
Intel® Server System SR9000MK4U Product Guide 711. Remove the top cover. For instructions, see “Removing the Top Cover” on page 36.2. Simultaneously p
72 Intel® Server System SR9000MK4U Product Guide4. If you are not installing a replacement power supply, insert the power supply filler panel (see let
Intel® Server System SR9000MK4U Product Guide 73Hot-swapping a Power SupplyTo perform this procedure, you will first need to remove the top cover. The
74 Intel® Server System SR9000MK4U Product Guide3. Disconnect the power cable from the power supply you want to replace. 4. Remove the power supply. F
Intel® Server System SR9000MK4U Product Guide 754. Determine your next course of action and refer to the appropriate steps:— If you have removed your
76 Intel® Server System SR9000MK4U Product GuideInstalling and Removing the Power Supply BoxBefore beginning these steps, power down your server syste
Intel® Server System SR9000MK4U Product Guide 771. Disconnect the CPU1 / CPU2 MVR cable from the main board. To disconnect this cable, press and hold