Intel MFS5000SIB Datenblatt Seite 42

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 50
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 41
Appendix B: Sensor Tables Intel® Compute Module MFS5000SI TPS
Revision 1.4
Intel order number: E15154-007
36
Table 16. Analog Sensor Thresholds
Name # Sensor Type Lower Critical
Lower Non-
Critical
Upper Non-
Critical
Upper Critical
BB Vtt 10h Voltage 1.90V
N/A N/A
1.5V
BB +1.5V AUX 11h Voltage 1.33V
N/A N/A
1.65V
BB +1.5V 12h Voltage 1.33V
N/A N/A
1.65V
BB +1.8V 13h Voltage 1.67V
N/A N/A
1.94V
BB +3.3V 14h Voltage 2.97V
N/A N/A
3.62V
BB +3.3V STB 15h Voltage 2.97V
N/A N/A
3.62V
BB +1.5V ESB 16h Voltage 1.33V
N/A N/A
1.65V
BB +5V 17h Voltage 4.5V
N/A N/A
5.5V
BB +12V AUX 18h Voltage 10.66V
N/A N/A
13.26V
BB 0.9V 19h Voltage 0.78V
N/A N/A
1.02V
DIMM 1-8
Temperature
50h –
57h
Temperature
N/A N/A 100ºC 105ºC
Processor 1
Core 1,2,3,4
Thermal Margin
(PECI)
92h –
93h
Temperature
N/A N/A N/A N/A
Processor 2
Core 1,2,3,4
Thermal Margin
(PECI)
94h –
95h
Temperature
N/A N/A N/A N/A
Processor 1,2
Thermal Ctrl %
9Ah,
9Bh
Temperature
N/A N/A N/A
50%
Seitenansicht 41