Datasheet 95
Register Description
2.13.7 MC_CLOSED_LOOP0
MC_CLOSED_LOOP1
MC_CLOSED_LOOP2
This register controls the closed loop thermal response of the DRAM thermal throttle
logic. It supports immediate thermal throttle and 2X refresh. In addition, the register is
used to configure the throttling duty cycle.
2.13.8 MC_THROTTLE_OFFSET0
MC_THROTTLE_OFFSET1
MC_THROTTLE_OFFSET2
Compared against bits [36:29] of virtual temperature of each rank stored in
RANK_VIRTUAL_TEMP to determine the throttle point. Recommended value for each
rank is 255.
When there are more than 4 ranks attached to the channel, the thermal throttle logic is
shared.
Device: 4, 5, 6
Function: 3
Offset: 84h
Access as a Dword
Bit Type
Reset
Value
Description
17:8 RW 64
MIN_THROTTLE_DUTY_CYC.
This parameter represents the minimum number of DCLKs of operation allowed
after throttling. In order to provide actual command opportunities, the number
of clocks between CKE de-assertion and first command should be considered.
4RW0
REF_2X_NOW.
Direct control of dynamic 2X refresh if
MC_THERMAL_CONTROL.THROTTLE_MODE = 2.
3:0 RW 0
THROTTLE_NOW.
Throttler Vector to directly control throttling if
MC_THERMAL_CONTROL.THROTTLE_MODE = 2.
Device: 4, 5, 6
Function: 3
Offset: 88h
Access as a Dword
Bit Type
Reset
Value
Description
31:24 RW 0
RANK3. Rank 3 throttle offset.
23:16 RW 0
RANK2. Rank 2 throttle offset.
15:8 RW 0
RANK1. Rank 1 throttle offset.
7:0 RW 0
RANK0. Rank 0 throttle offset.